 HF-S 218 PL-T/C II SR 220-240V 50/60Hz
Product code: 58432 Line Frequency: 50/60 Hz T-case maximum: 75 (max) C Full product code: 913713035866 Full product name: HF-S 218 PL-T/C II SR 220-240V 50/60Hz Order code: 913713035866 Order product name: HF-S 218 PL-T/C II SR 220-240V 50/60Hz Packing configuration: 12 Pieces per pack: 1 Bar code on outerbox - EAN3: 8718291169642 Bar code on pack - EAN1: 8718291169635 see more »
Packs per outerbox: 12 Logistic code(s) - 12NC: 913713035866 Net weight per piece: 0.156 kg Length A1: 125.5 mm CE marking: Yes Height C1: 32.0 mm T-ambient: -25 (min), 50 (max) C Width B1: 67.8 mm Lifetime 90% surv.@Tcaselife: 50000 hr Fixing Hole Diameter D1: 4.0 mm Fixing Hole Distance Length A2: 93.5 mm ENEC certificate: Yes Fixing Hole Distance Width B2: 57.5 mm Inrush current Peak: 18 (max) A Earth leakage current: 0.5 (max) mA Inrush current Width: 0.25 ms T-storage: -40 (min), 80 (max) C Rated Lamptype: PL-T/C Line Voltage: 220-240 V Rated Ballast-Lamp Power: 18 Rated Number of Lamps: 2 piece T-case life: 75 C Approval marks: ENEC / CE / VDE-EMC Automatic restart: Yes Energy Efficiency Index: A2 Housing: L 125.5x67.8x32.0 Mains voltage safety (AC): 198...264V Operating frequency *: 45 kHz Mains voltage performance (AC): 202...254V Ballast Lumen Factor: 1 - Power losses gear: 1.17 W PowerFactor 100% output power: 0.95 - Overvoltage protection 320Vac: 48 hr Overvoltage protection 350Vac: 2 hr Crestfactor: 1.7 - Max ballast on MCB(16A type B): 28 x Hum and Noise level: 30 dB(A) Conn.type input terminals: WAGO 250 connector [Suitable for manual wiring] Conn.type output terminals: WAGO 250 connector [Suitable for manual wiring] Max. cable length Hot Wires: 1 m Striplength: 8.5-9.5 mm Wcs Input terminals: 0.75-1.50 mm2 Wcs Output terminals: 0.75-1.50 mm2 Cable-Cap cold out-wires-earth: 100 pF Cable-Cap hot out-wires-earth: 100 pF F-marking: No Bumps: IEC 60068-2-29 test Eb EMI 9kHz .. 30 MHz: EN55015 Vibrations: IEC 60068-2-6 test Fc C-Tick certificate: No CCC certificate: No PSB certification: No TISI marking: No CB Certificate: No SIRIM approval: No Application code: II SR Humidity: IEC 61347-2-3 Rated Lamp Power on PL-T/C: 18 System Power on PL-T/C: 18.7 Power Loss on PL-T/C: 0.7 Lamp Power on PL-T/C: 18 Bal Lm Fac Emergency operation: 0.90 - Light output after 5 sec: 50% of EBLF Light output after 60 sec: 100% of EBLF Normal operating voltage (DC): 220-240 V Batt volt guaranteed ignition: 186-275 V Batt volt guaranteed operation: 176-275 V Preheat time: 1.95 s VDE certificate: Yes « hide more
€ 14,84 € 14,84 ex. VAT
pc(s)
pc(s)
 HF-S 226 PL-T/C/L/TL5C II SR 220-240V
Product code: 58433 Line Frequency: 50/60 Hz T-case maximum: 75 (max) C Full product code: 913713035666 Full product name: HF-S 226 PL-T/C/L/TL5C II SR 220-240V Order code: 913713035666 Order product name: HF-S 226 PL-T/C/L/TL5C II SR 220-240V Packing configuration: 12 Pieces per pack: 1 Bar code on outerbox - EAN3: 8718291169604 Bar code on pack - EAN1: 8718291169598 see more »
Packs per outerbox: 12 Logistic code(s) - 12NC: 913713035666 Net weight per piece: 0.165 kg Length A1: 125.5 mm CE marking: Yes Height C1: 32.0 mm T-ambient: -25 (min), 50 (max) C Width B1: 67.8 mm Lifetime 90% surv.@Tcaselife: 50000 hr Fixing Hole Diameter D1: 4.0 mm Fixing Hole Distance Length A2: 93.5 mm ENEC certificate: Yes Fixing Hole Distance Width B2: 57.5 mm Inrush current Peak: 18 (max) A Earth leakage current: 0.5 (max) mA Inrush current Width: 0.25 ms T-storage: -40 (min), 80 (max) C Rated Lamptype: PL-T/C/L/TL5C Line Voltage: 220-240 V Rated Ballast-Lamp Power: 26 Rated Number of Lamps: 2 piece T-case life: 75 C Approval marks: ENEC / CE / VDE-EMC Automatic restart: Yes Energy Efficiency Index: A2 Housing: L 125.5x67.8x32.0 Mains voltage safety (AC): 198...264V Operating frequency *: 45 kHz Mains voltage performance (AC): 202...254V Ballast Lumen Factor: 1 - Power losses gear: 4.25 W PowerFactor 100% output power: 0.95 - Overvoltage protection 320Vac: 48 hr Overvoltage protection 350Vac: 2 hr Crestfactor: 1.7 - Max ballast on MCB(16A type B): 28 x Hum and Noise level: 30 dB(A) Conn.type input terminals: WAGO 250 connector [Suitable for manual wiring] Conn.type output terminals: WAGO 250 connector [Suitable for manual wiring] Max. cable length Hot Wires: 1 m Striplength: 8.5-9.5 mm Wcs Input terminals: 0.75-1.50 mm2 Wcs Output terminals: 0.75-1.50 mm2 Cable-Cap cold out-wires-earth: 100 pF Cable-Cap hot out-wires-earth: 100 pF F-marking: No Bumps: IEC 60068-2-29 test Eb EMI 9kHz .. 30 MHz: EN55015 Vibrations: IEC 60068-2-6 test Fc C-Tick certificate: No CCC certificate: No PSB certification: No TISI marking: No CB Certificate: No SIRIM approval: No Application code: II SR Humidity: IEC 61347-2-3 Rated Lamp Power on PL-T/C: 26 System Power on PL-T/C: 30.3 Power Loss on PL-T/C: 4.3 Lamp Power on PL-T/C: 26 Bal Lm Fac Emergency operation: 0.90 - Light output after 5 sec: 50% of EBLF Light output after 60 sec: 100% of EBLF Normal operating voltage (DC): 220-240 V Batt volt guaranteed ignition: 186-275 V Batt volt guaranteed operation: 276-275 V Preheat time: 1.93 s VDE certificate: Yes « hide more
€ 14,84 € 14,84 ex. VAT
pc(s)
pc(s)

HF-Selectalume II independent version is the most cost-effective, reliable, slim and affordable fluorescent solution, with highly disruptive technology for energy saving, system flexibility and unsurpassed performance. The cost-saving HF-Selectalume II PLTC SR has a robust design which meets all relevant international safety and performance standards. The HF-S II strain relief is optimized mainly for PL-T/C lamps.HF-Selectalume II is intended for use with indoor lighting fixtures such as spotlights, downlights and recessed luminaries, which are largely used in office, retail, industry, hotel, restaurant and other applications.

Features

Complies with CE and ENEC (only for 2-lamp ballasts)
Robust design – over 70,000 hours lifetime at Ta=50 ˚C and over 50,000 on/off switching operations on one lamp (only for 2-lamp ballasts)
Energy efficiency class: A2
Active power factor correction to ensure constant light, irrespective of mains-voltage fluctuations (only for 2-lamp ballasts)

Applications

Commercial indoor lighting applications such as retail stores, office buildings, supermarkets, hotels, convenience stores and industrial premises with long operating hours (e.g. in corridors)
In luminaires of protection class I and II such as spotlights, downlights and recessed
Suitable for operation with movement-detection control systems like Philips OccuSwitch or in applications with frequentswitching activity (on/off) (only for 2-lamp ballasts)

If you buy goods in partial package that is not currently available in our store (available on request), we reserve the rights to charge additional increments of 5 EUR ex. VAT.

Recommended also

 Philips HF-Essential for TL5/TL-D
Rated 5.0/5 based on 1 customer reviews
from 7,48
Electronic ballast, A2 energy efficient class Kanlux BL
Rated 5.0/5 based on 1 customer reviews
from 7,77
 Philips HF-Selectalume II for TL-D
Rated 5.0/5 based on 1 customer reviews
from 9,63
 Osram QUICKTRONIC QTz8
Rated 5.0/5 based on 1 customer reviews
from 9,00
 Tridonic PC T8 TEC, 18 - 58 W
Rated 5.0/5 based on 1 customer reviews
from 7,08
 Philips HF-Matchbox Blue
Rated 5.0/5 based on 1 customer reviews
from 7,30
 Tridonic PCA T5 ECO lp xitec II, 14 - 80 W
Rated 5.0/5 based on 1 customer reviews
from 35,83
 Tridonic PC TCL PRO, 18 - 55 W
Rated 5.0/5 based on 1 customer reviews
from 13,32
 Tridonic PC TC PRO sr+, 1/2x11 - 42 W
Rated 5.0/5 based on 1 customer reviews
from 14,93
 Tridonic PCA T5 BASIC lp xitec II, 14 - 80 W
Rated 5.0/5 based on 1 customer reviews
from 31,64
 Tridonic PC TC PRO, 1/2x9 - 70 W
Rated 5.0/5 based on 1 customer reviews
from 14,16
 Tridonic PC INDUSTRY, 36 – 80 W
Rated 5.0/5 based on 1 customer reviews
from 39,73
HF-Selectalume II for PL-T/C Strain Relief
Rated 5.0/5 based on 1 customer reviews
Power Supplies, Ballasts, Transformers / Fluorescent Electronic Gear

Philips https://www.gitlighting.com/uploads/producer_logos/faeccaa67c65b0428b3eca6021a3815d.jpg

HF-Selectalume II for PL-T/C Strain Relief
60.10 PLN available
 Philips HF-Selectalume II for  PL-T/C Strain Relief

Recommended

LED street luminaire GitLighting WHL COB Epistar
Rated 5.0/5 based on 1 customer reviews
from 52,35
 GitLighting Gemini 22 Solar Street Light 40xLED, 24W, 2500lm, 3 modes
Rated 5.0/5 based on 1 customer reviews
361,79
Ceiling light luminaire Kanlux ARDEA
Rated 5.0/5 based on 1 customer reviews
from 5,62
 Lena Lighting Corona Lite Led
Rated 5.0/5 based on 1 customer reviews
from 112,45
Hermetic wall & ceiling light luminaire Kanlux MARC DL-60
Rated 5.0/5 based on 1 customer reviews
9,19
 GitLighting Gemini 18 LED Solar Street Light 1300lm, 3 modes
Rated 5.0/5 based on 1 customer reviews
208,76
LED street luminaire GitLighting With Brigdelux LEDs
Rated 5.0/5 based on 1 customer reviews
from 112,66
Microwave movement sensor Kanlux ROLF MINI JQ-L
Rated 5.0/5 based on 1 customer reviews
8,83

Blog posts

Osram and Philips light sources types

Wondering how to select a light source for luminaire? Below is a list of popular light sources of Osram and Philips with base information and the light source indication. Fluorescent Linear and Circular   Base Power (W) Luminous flux (lm) OSRAM PHILIPS Fluorescent Linear T5 (T16) G5 8 400 Basic T5Short L 8W TL MiniStandard TL Mini 8W 14 200... read more »


Our other brands

Elektriko.pl - oprawy oświetleniowe i źródła światła Electric24.pl Hydrauliko.pl

e-Gazele Biznesu 37. place in Poland in the ranking e-Gazele Biznesu 2016.
"Golden Payer 2015" award from Euler Hermes.
Golden payer Golden payer 2016 Export

Logisoft company has 14 years - we began 14 August 2006. 19660 companies have trusted us. We offer 7 934 products.

On-line payments